Dark Light
,

ATEN 15A/10A 8-Outlet 1U Metered eco PDU PE5108


• 1U 8-Outlet eco PDU
• Bank level metering

ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE5108 eco PDUs are intelligent PDUs that contain 8 AC outlets and are available in various IEC or NEMA socket configurations. They provide secure, centralized, intelligent, power management of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center’s health environment via sensors*.

  • Connections
  • Support 10/100Mbit Ethernet Interface
  • Support TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and SNMP V1,V2&V3
  • Support 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS
  • Support : eco DC, Browser (IE, Firefox, Chrome, Safari)
  • Metering
  • Bank level power metering and monitoring
  • Environment Monitoring : support external temperature/temperature & humidity sensors for rack temperature and humidity monitoring
  • Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
SKU: ATE_PE5108 Categories: ,
Function PE5108A PE5108B PE5108G
Electrical
Nominal Input Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Input Current 15A Max; 12A(UL de-rated) 15A Max; 12A(UL de-rated) 10A Max
Input Frequency 50-60 Hz 50-60 Hz 50-60 Hz
Input Connection NEMA 5-15P NEMA 6-15P IEC 60320 C14
Input Power 1800 VA(Max); 1440 VA(UL de-rated) 3120 VA(Max); 2496 VA(UL de-rated) 2300 VA(Max)
Outlet Type Total: 8 x NEMA 5-15R Total: 8 x IEC320 C13 Total: 8 x IEC320 C13
Nominal Output Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Output Current (Outlet) NEMA 5-15R: 15A(Max); 12A(UL de-rated) C13 : 15A(Max); 12A(UL de-rated) C13 : 10A(Max)
Maximum Output Current (Bank) 15A(Max); 12A(UL de-rated) 15A(Max); 12A(UL de-rated) 10A(Max)
Maximum Output Current (Total) 15A(Max); 12A(UL de-rated) 15A(Max); 12A(UL de-rated) 10A(Max)
Breakers 1 x 15A Non-Fuse Breaker 1 x 15A Non-Fuse Breaker 1 x 15A Non-Fuse Breaker
Metering Bank level Current, Voltage, VA , PF and KWh Monitoring Bank level Current, Voltage, VA , PF and KWh Monitoring Bank level Current, Voltage, VA , PF and KWh Monitoring
Outlet Switching None None None
Environment Sensor Ports 2 2 2
Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) 43.24 x 4.40 x 21.93 cm 43.24 x 4.40 x 21.93 cm 43.24 x 4.40 x 21.93 cm
Weight 2.77 kg 2.82 kg 2.82 kg
Power Cord Length 3 m 3 m 3 m
Environmental
Temperature (Operating / Storage) 0 – 50°C / -20 – 60°C 0 – 50°C / -20 – 60°C 0 – 50°C / -20 – 60°C
Humidity (Operating & Storage) 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing
Compliance
EMC Verification FCC, Others by Request FCC, Others by Request CE, Others by Request
Safety Verification TUV-CB, cTUVus, UL, Others by Request TUV-CB, cTUVus, UL, Others by Request TUV-CB, CE-LVD, Others by Request