ATEN 20A/16A 16-Outlet Metered & Switched eco PDU PE6216


ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE6216 eco PDUs are intelligent PDUs that contain 16 AC outlets and are available in various IEC or NEMA socket configurations.

The series provides secure, centralized, intelligent power management (power on / off / cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center’s health environment via sensors*.

  • Power Distribution
  • Space saving 0U rack mount design with rear mounting
  • IEC or NEMA outlet models
  • 3 x 7-segment front panel LED shows Current / IP Address for PDU / Bank
  • Remote users can monitor PDU/Bank status via web pages on their browsers
  • Safe shutdown support
  • Separate power for the unit´s own power and its power outlets – the user interface is still accessible even when an overload condition trips the devices´ circuit breaker

    Remote Access

  • Remote power control via TCP/IP and a built in 10/100 Ethernet port
  • Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping, Telnet
  • Energy & DCIM Management Web GUI – eco DC
  • Supports SNMP Manager V1, V2 & V3

    Operation

  • Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets
  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
  • Easy setup and operation via a browser-based user interface
  • Multibrowser support (IE, Firefox, Chrome, Safari, Opera, Netscape)
  • RTC support to keep the timer running during times of no power.
  • Up to 8 user accounts and 1 administrator account
  • Proactive Overload Protection (POP) – automatically powers off outlets when current overloads to protect operating devices

    Management

  • Power status measurement at the PDU/Bank level
  • LED indicators for current and IP address at the PDU device and/or Bank levels
  • Real-time aggregate current, voltage, and power and power dissipation displayed in a browser-based UI for monitoring at the PDU level
  • Environment monitoring – supports external temperature / humidity / Differential Pressure sensors for rack environment monitoring
  • Current and voltage threshold setting
  • Naming support for outlets
  • User outlet access assignment on an outlet-by-outlet basis
  • Event logging and syslog support
  • Upgradeable firmware
  • Multilanguage support: English, Traditional Chinese, Simplified Chinese, Japanese, German, Italian, Spanish, French, Russian

    Security

  • Two-level password security
  • Strong security features include strong password protection and advanced encryption technologies – 128 bit SSL
  • Remote authentication support: RADIUS

    eco DC Energy & DCIM Management Web GUI*

  • Automatic discovery of all PE devices within the same intranet
  • Remote real-time power measurement and monitoring
  • Remote real-time environment sensor monitoring
  • Plotting/Monitoring of all PE devices
  • Exceed threshold alert through SMTP and System log
  • Power Analysis Report

    *eco DC is designed to work with eco PDUs, and is bundled with all PE series packages.

SKU: ATE_PE6216 Categories: ,
Function PE6216A PE6216B PE6216G
Electrical
Nominal Input Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Input Current 20A(Max) 20A(Max) 16A(Max)
Input Frequency 50-60 Hz 50-60 Hz 50-60 Hz
Input Connection NEMA 5-20P NEMA 6-20P IEC 60320 C20
Input Power 2400 VA(Max) 4160 VA(Max) 3680 VA(Max)
Outlet Type Total: 14 x NEMA 5-15R + 2 x NEMA 5-20R
Bank1-1: Outlet 1 – 8; 7 x NEMA 5-15R + 1 x NEMA 5-20R
Bank1-2: Outlet 9 – 16; 7 x NEMA 5-15R + 1 x NEMA 5-20R
Total: 14 x IEC320 C13 + 2 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Total: 14 x IEC320 C13 + 2 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Nominal Output Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Output Current (Outlet) NEMA 5-15R: 15A(Max)
NEMA 5-20R: 20A(Max)
C13: 15A(Max)
C19: 20A(Max)
C13: 10A(Max)
C19: 16A(Max)
Maximum Output Current (Bank) 20A(Max) 20A(Max) 16A(Max)
Maximum Output Current (Total) 20A(Max) 20A(Max) 16A(Max)
Breakers 1 x 20A Non-Fuse Breaker 1 x 20A Non-Fuse Breaker 1 x 16A Non-Fuse Breaker
Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring Bank Level Current, Voltage, VA , PF and kWh Monitoring Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching Yes Yes Yes
Environment Sensor Ports 2 2 2
Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) 132.48 x 6.60 x 4.40 cm
(52.16 x 2.6 x 1.73 in.)
132.48 x 6.60 x 4.40 cm
(52.16 x 2.6 x 1.73 in.)
132.48 x 6.60 x 4.40 cm
(52.16 x 2.6 x 1.73 in.)
Weight 3.73 kg ( 8.22 lb ) 3.73 kg ( 8.22 lb ) 3.73 kg ( 8.22 lb )
Power Cord Length 3 m 3 m 3 m
Environmental
Temperature (Operating / Storage) 0–50°C / -20–60°C 0–50°C / -20–60°C 0–40°C / -20–60°C
Humidity (Operating & Storage) 0–80% RH, Non-Condensing 0–80% RH, Non-Condensing 0–80% RH, Non-Condensing
Compliance
EMC Verification FCC, Others by Request FCC, Others by Request CE, C-Tick, Others by Request
Safety Verification cTUVus, PSE, Others by Request cTUVus, PSE, Others by Request TUV-CB, GOST, Others by Request