ATEN 30A/32A 24-Outlet Metered eco PDU PE5324


As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE5324 eco PDU is an intelligent PDU that contains 24 AC outlets and is available in various IEC or NEMA socket configurations. It provides the ability to monitor the center’s health environment via sensors*.

NRGence eco PDU offers real-time power measurement – allowing you to monitor the power status of devices attached to the PDUs, either at the PDU device or Bank level, from practically any location via a TCP/IP connection. It also offers comprehensive power analysis reports – providing precise measurements of current, voltage, power and watt-hour in a real-time Display.

  • Power Distribution
  • Space saving 0U rack mount design with rear mounting
  • IEC or NEMA outlet models
  • 3 x 7-segment front panel LED shows Current / IP Address for PDU / Bank
  • Remote users can monitor PDU/Bank status via web pages on their browsers
  • Safe shutdown support
  • Separate power for the unit´s own power and its power outlets – the user interface is still accessible even when an overload condition trips the devices´ circuit breaker

    Remote Access

  • Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping, Telnet
  • eco PDU Power Management software – eco Sensors
  • Supports SNMP Manager V1, V2 & V3

    Operation

  • Easy setup and operation via a browser-based user interface
  • Multibrowser support (IE, Mozilla, Firefox, Chrome, Safari, Opera, Netscape)
  • RTC support to keep the timer running during times of no power
  • Up to 8 user accounts and 1 administrator account

    Management

  • Power status measurement at the PDU/Bank level
  • LED indicators for current and IP address at the PDU device and/or Bank levels
  • Real-time aggregate current, voltage, and power and power dissipation displayed in a browser-based UI for monitoring at the bank level
  • Environment monitoring – supports external temperature / humidity / Differential Pressure sensors for rack environment monitoring
  • Current and voltage threshold setting
  • Naming support for outlets
  • Event logging and syslog support
  • Upgradeable firmware
  • Multilanguage support: English, Traditional Chinese, Simplified Chinese, Japanese, German, Italian, Spanish, French, Russian

    Security

  • Two-level password security
  • Strong security features include strong password protection and advanced encryption technologies – 128 bit SSL
  • Remote authentication support: RADIUS

    eco Sensors Energy Management Software*

  • Automatic discovery of all PE devices within the same intranet
  • Remote real-time power measurement and monitoring
  • Remote real-time environment sensor monitoring
  • Plotting/Monitoring of all PE devices
  • Exceed threshold alert through SMTP and System log
  • Power Analysis Report

    *eco Sensors is designed to work with NRGence™ PDUs, and is bundled with all PE series packages

SKU: ATE_PE5324 Categories: ,
Electrical
Nominal Input Voltage 100 – 240 VAC
Maximum Input Current 32A(Max)
Input Frequency 50-60 Hz
Input Connection For G Plug :
IEC 60309 32A
Input Power 7360 VA(Max)
Outlet Type Total: 21 x IEC320 C13 + 3 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Nominal Output Voltage 100 – 240 VAC
Maximum Output Current (Outlet) C13: 10A(Max)
C19: 16A(Max)
Maximum Output Current (Bank) 16A(Max)
Maximum Output Current (Total) 32A(Max)
Breakers 2 x 16A UL489 Breaker
Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching None
Environment Sensor Ports 2
Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) 177.50 x 6.60 x 4.40 cm
(69.88 x 2.6 x 1.73 in.)
Weight 5.82 kg ( 12.82 lb )
Power Cord Length 1.6 m
Environmental
Temperature (Operating / Storage) 0–40°C / -20–60°C
Humidity (Operating & Storage) 0–80% RH, Non-Condensing
Compliance
EMC Verification CE, C-Tick, Others by Request
Safety Verification TUV-CB, GOST, Others by Request