ATEN Basic 1U PDU with surge protection PE0210S


The Aten’s PE0210S, a 10-outlet, 1U rack mount power distribution unit (PDU), provides IEC and NEMA output. It distributes power to 10 receptacles from a single plug with unfiltered electrical pass-through. The PE0210S also provides surge protection, prevents damage to your equipment from power surges and spikes. The integrated surge protector includes a LED indicator, letting you know the status of your equipment.

  • Space saving -1U rack mount design
  • IEC or NEMA outlet models
  • Surge Protection
  • Over-current Protection
  • Aluminum material
  • Works with data centers, server rooms and telecom equipment
SKU: ATE_PE0210S Categories: ,
Function PE0210SA PE0210SB PE0210SG
Electrical
Nominal Input Voltage 100-120 VAC 100-240 VAC 100-240 VAC
Maximum Input Current 20A Max
(UL de-dated 16A Max)
20A Max
(UL derating 16A Max)
16A (Max)
Input Frequency 50-60 Hz 50-60 Hz 50-60 Hz
Input Connection For A Plug: NEMA L5-20P
For A2 Plug:NEMA 5-20P
NEMA L6-20P For G Plug: IEC-320 C20
For Z Plug: Chinese 16A
Input Power 2400VA(Max);
1920VA(UL de-rated)
4800VA(Max);
3840VA(UL de-rated)
3840VA(Max)
Outlet Type (10) NEMA 5-20R (10) IEC 320 C13 (10) IEC 320 C13
Maximum Output Current (Outlet) 20A Max
(UL de-dated 16A Max)
15A Max
(UL derating 12A Max)
10A (Max)
Maximum Output Current (Bank) 20A Max
(UL de-dated 16A Max)
20A Max
(UL derating 16A Max)
16A (Max)
Maximum Output Current (Total) 20A Max
(UL de-dated 16A Max)
20A Max
(UL derating 16A Max)
16A (Max)
OPD(Overcurrent Protection Device) Yes Yes Yes
Physical Properties
Dimensions (L x W x H) 48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)
48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)
48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)
Weight 0.67 kg ( 1.48 lb ) 0.67 kg ( 1.48 lb ) 0.67 kg ( 1.48 lb )
Power Cord Length 10ft(12#) 10ft(12#) 10ft(3*2.5mm2)
Environmental
Temperature (Operating / Storage) 0 – 40℃ / -20 – 60℃
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
0 – 40℃ / -20 – 60℃
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
0 – 40℃ / -20 – 60℃
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
Elevation (Operating / Storage) 3000m 3000m 3000m
Compliance
EMC Verification FCC Class A FCC Class A
Safety Verification By Request By Request LVD