Dark Light
,

ATEN eco PDU PE8216r


As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE8216r eco PDUs are intelligent PDUs that contain 16 AC outlets and are available in various IEC or NEMA socket configurations.

NRGence eco PDUs provide secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center’s health environment via sensors *.

NRGence eco PDUs offer remote power control combined with real-time power measurement – allowing you to control and monitor the power status of devices attached to the PDUs, either at the PDU device, bank, or outlet level, depending on the model, from practically any location via a TCP/IP connection **.

  • Connections
  • Supports 10/100Mbit Ethernet, Modem, RS-232, Daisy Chain interface
  • Supports TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, STP, DCHP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2&V3, IPv6
  • Supports three-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS, TACACS+, LDAP, LDAPS and Active
  • Directory
  • Supports CC2000, eco Sensors, Java API, multiple Browsers (IE, Firefox, Chrome, Safari), OOBC/RS232
  • Metering
  • PDU and outlet level power metering and monitoring
  • Environment monitoring – supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoring
  • Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
  • Outlet Switch Control
  • Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
  • Outlet group support at the PDU and daisy chain level
  • Daisy chain with PON In – PON Out port
  • On/Off scheduling for individual outlets and outlet groups – power management tasks can be scheduled on a daily, weekly, monthly, or user-speci¬ ed basis
  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-On sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order
SKU: ATE_PE8216r Categories: ,
Function PE8216rB PE8216rG
Electrical
Nominal Input Voltage 100 – 240 VAC 100 – 240 VAC
Maximum Input Current 20A Max; 16A(UL de-rated) 16A Max
Input Frequency 50-60 Hz 50-60 Hz
Input Connection NEMA 6-20P IEC 60320 C20
Input Power 4160 VA(Max); 3328 VA(UL de-rated) 3680 VA(Max)
Outlet Type Total: 14 x IEC320 C13 + 2 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Total: 14 x IEC320 C13 + 2 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Nominal Output Voltage 100 – 240 VAC 100 – 240 VAC
Maximum Output Current (Outlet) C13: 15A (Max); 12A(UL de-rated)
C19: 20A (Max); 16A(UL de-rated)
C13: 10A (Max)
C19: 16A (Max); TUV De-rated 15A(Max)
Maximum Output Current (Bank) 20A(Max); 16A(UL de-rated) 16A(Max); TUV De-rated 15A(Max)
Maximum Output Current (Total) 20A(Max); 16A(UL de-rated) 16A(Max); TUV De-rated 15A(Max)
Breakers 1 x 20A Non-Fuse breaker 1 x 16A Non-Fuse breaker
Metering Outlet Level Current, Voltage, VA, PF, KWh Monitoring Outlet Level Current, Voltage, VA, PF, KWh Monitoring
Outlet Switching Yes Yes
Environment Sensor Ports 4 4
Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) 132.5 x 6.6 x 4.4 cm 132.5 x 6.6 x 4.4 cm
Weight 3.9 kg 3.9 kg
Power Cord Length 1.6 m 1.6 m
Environmental
Temperature (Operating / Storage) 0 – 50°C / -20 – 60°C 0 – 40°C / -20 – 60°C
Humidity (Operating & Storage) 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing
Compliance
EMC Verification FCC Part 15 Class A, Others by Request CE, C-Tick, Others by Request
Safety Verification cTUVus, PSE, Others by Request TUV-CB, GOST, Others by Request