ATEN Energy & DCIM Management Software eco Sensors


eco Sensors software has been developed to work with ATEN’s new generation of PE series green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. With the use of dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI) by zone, eco Sensors software, in conjunction with sensor-enabled eco PDUs, gives you the means to assess, diagnose and estimate how much energy you can save. Following the suggestions generated by the sensor-enabled system allows you to optimize energy usage to save energy without harming your IT equipment’s reliability. The eco Sensors utility provides single portal, single login, secure, centralized, access, administration and management of up to 2500 PE devices over the network – local and worldwide – anywhere and anytime.

  • Automatic discovery of all PE devices within the same intranet
  • Remote real-time power measurement and monitoring
    – PDU level current / voltage / power dissipation / power consumption
    – Outlet ON / OFF / Recycle status
  • Second window to monitor data center status including PUE, RTI, RCI, Power, Carbon Footprint and rack status
  • Remote real-time power outlet management
    – Power outlet ON / OFF / Cycle switching by outlet or user-defined group
    – Power outlet ON / OFF / Cycle switching with pre-defined schedule
    – User-defined outlet level delays for sequential power up
    – Current / Voltage / Power Dissipation / Power Consumption threshold level setting
    – User access assignment for every outlet
    – Name assignment to individual outlets
  • Remote real-time environment sensor monitoring
    – Temperature / Temperature + Humidity reading / Temperature + Differential Pressure
    – Temperature and Humidity threshold level setting
  • Plotting/Monitoring of all PE devices
    – Add data center server racks
    – Add PE devices for each server rack
    – Manage device/device outlet status for each plot
  • Offers essential data center indices including Rack Intake Temperature, Rack Exhaust Temperature, Rack Equipment Temperature Difference, RCI ( Rack Cooling Index ), RTI ( Return Temperature Index ), RHI ( Rack Humidity Index ), RPI ( Rack Pressure Index ), RAI ( Rack Airflow Index )
  • Power analysis report for optimizing data center energy management – including power usage, power load, power cost, CO2 cost, power capacity and trend
  • Exceed threshold alert through SMTP and System log
  • 10240 line event log
  • System log provision
  • Two-level password security
  • Strong security features include password protection and advanced encryption technologies – 128 bit SSL
Max PDU number 2500
Data Center Layout 45 x 30 / 72 x 48 / 90 x 60
Max RACK Number 1250
Max Zone Number 128
Power Report Data 3 years
Real Time Dashboard Data 1 hour