- Connections
- Supports 10 / 100M bit Ethernet interface
- Supports TCP / IP, UDP, HTTP, HTTPS, SSL, DHCP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2 and V3
- Supports three-level account / password security, IP / MAC filter, 128 bit SSL, and RADIUS
- Supports CC2000, eco DC, multiple browsers (IE, Firefox, Chrome, and Safari)
- Metering
- PDU and outlet level power metering and monitoring
- Environment monitoring – supports external temperature / temperature and humidity sensors for rack temperature and humidity monitoring
- Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
- Supports door sensor
- Outlet Switch Control
- Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
- Outlet group support at the PDU level
- On / Off scheduling for individual outlet and outlet groups. Power management tasks can be scheduled on a daily, weekly, or user-specifi ed time basis
- Supports multiple power control methods — Wake on LAN, System After AC Back, Kill the Power
- Power-On sequencing — users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order
- Proactive overload protection (POP) – automatically powers off the last outlet that causes the current overload while allowing users to set shutdown priority
Power Distribution & Rack Solutions, Rack PDU
ATEN 20A/16A 16-Outlet Outlet-Metered & Switched eco PDU PE8216
ATEN’s NRGence line-up is a new generation of green energy power distribution units (eco PDUs) that optimize the efficiency of data center power usage. The PE8216 eco PDUs are intelligent PDUs that contain 16 AC outlets and are available in various IEC / NEMA socket configurations. These models feature proactive overload protection to automatically power off the last outlet that causes the current overload while allowing users to set shutdown priority.
Function | PE8216B | PE8216G |
Electrical | ||
Nominal Input Voltage | 100 – 240 VAC | 100 – 240 VAC |
Maximum Input Current | 20A Max; 16A(UL de-rated) | 16A Max |
Input Frequency | 50-60 Hz | 50-60 Hz |
Input Connection | NEMA 6-20P | IEC 60320 C20 |
Input Power | 4160 VA(Max); 3328 VA(UL de-rated) | 3680 VA(Max) |
Outlet Type | Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 |
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 |
Nominal Output Voltage | 100 – 240 VAC | 100 – 240 VAC |
Maximum Output Current (Outlet) | C13: 15A (Max); 12A(UL de-rated) C19: 20A (Max); 16A(UL de-rated) |
C13: 10A (Max) C19: 16A (Max) |
Maximum Output Current (Bank) | 20A(Max); 16A(UL de-rated) | 16A(Max) |
Maximum Output Current (Total) | 20A(Max); 16A(UL de-rated) | 16A(Max) |
Breakers | 1 x 20A Non-Fuse breaker | 1 x 16A Non-Fuse breaker |
Metering | Outlet Level Current, Voltage, VA, PF, KWh Monitoring | Outlet Level Current, Voltage, VA, PF, KWh Monitoring |
Outlet Switching | Yes | Yes |
Environment Sensor Ports | 4 | 4 |
Metering Accuracy | Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
Physical Properties | ||
Dimensions (L x W x H) | 132.48 x 6.60 x 4.40 cm (52.16 x 2.6 x 1.73 in.) |
132.48 x 6.60 x 4.40 cm (52.16 x 2.6 x 1.73 in.) |
Weight | 3.88 kg ( 8.55 lb ) | 3.88 kg ( 8.55 lb ) |
Power Cord Length | 3 m | 3 m |
Environmental | ||
Temperature (Operating / Storage) | 0 – 50°C / -20 – 60°C | 0 – 40°C / -20 – 60°C |
Humidity (Operating & Storage) | 0 – 80% RH, Non-Condensing | 0 – 80% RH, Non-Condensing |
Compliance | ||
EMC Verification | FCC Part 15 Class A, Others by Request | CE, Others by Request |
Safety Verification | TUV-CB, Others by Request | TUV-CB, CE-LVD, Others by Request |